CM4 + ADS1115 (2 channels, single-ended A0/A1) + Adafruit 128x64 OLED bonnet.
Features
- Live value of both channels, converted by a selectable formula.
- Formula files:
<name>.txt, line 1 = unit, line 2 = expression inV(e.g.degC/V * 100). Functions: sqrt, log, ln, log10, log2, exp, abs, sin, cos, tan, asin, acos, atan, pow, min, max, round; constants pi, e. Invalid files are skipped. - On-screen menu: A or joystick press opens it, up/down selects, left/right changes a
value, B goes back. Items: formula per channel, N (seconds between timestamped records in the CSV / future DB), ADC range,
display refresh period, USB logging. Settings persist in
settings.json. - Plug in a USB stick: valid
formulas/*.txton it are copied to the Pi. With USB log: ON, readings are written tovoltmeter_logs/log_<time>.csvon the stick (new file per insertion; header + one row per reading). Screen showsRECwhile logging.
Configuration
config.yaml(default~/voltmeter/config.yaml, or--config): device-level setup, read once at startup. Covers ADC/OLED I2C bus and address, button GPIO pins, USB mount roots and the formula/log folder names on the stick, plus thedatabase:section for TigerData publishing. Every key is optional; see config.yaml for defaults. Bad values stop startup with a clear message; unknown keys are warned about and ignored.settings.json: user preferences changed from the on-screen menu (not for hand editing).
TigerData (Grafana dashboard backend)
- Create a service at tigerdata.com and note its host, port, dbname and user.
- In
config.yamlsetdatabase.enabled: trueanddatabase.host(plus the other fields). - Install the driver:
pip install '.[tigerdata]'. - Provide the password via environment, never in the file:
export VOLTMETER_DB_PASSWORD=...(for systemd, putVOLTMETER_DB_PASSWORD=...in/etc/voltmeter.env,chmod 600; the unit loads it if present).
The table (readings by default) is created automatically as a hypertable, one row per channel
per record (every N seconds): time, device_id, channel, volts, unit, formula. volts is the input voltage (after the
divider); the formula is a label only, so apply it in the query (e.g. 10 ^ ((volts - 7.75)/0.75 - 0.125)).
device_id defaults to the hostname, so several devices can share a table. In Grafana add a
PostgreSQL/TimescaleDB data source and query, e.g.:
SELECT time, volts FROM readings
WHERE device_id = 'pi-1' AND channel = 0 AND $__timeFilter(time) ORDER BY time
Uploads run on a background thread in batches. If the network drops, rows buffer in memory
(up to max_buffer, oldest dropped beyond) and are sent on reconnect; duplicates are
impossible on retry. The buffer is not persisted, so a power loss while offline loses the
unsent rows (the USB CSV is the durable copy).
Pi setup
sudo raspi-config nonint do_i2c 0 # enable I2C
python3 -m venv ~/voltmeter-venv && ~/voltmeter-venv/bin/pip install '.[pi]'
mkdir -p ~/voltmeter/formulas && cp formulas/*.txt ~/voltmeter/formulas/ && cp config.yaml ~/voltmeter/
# edit User/paths in deploy/voltmeter.service if your user is not "admin"
sudo cp deploy/voltmeter.service /etc/systemd/system/ && sudo systemctl daemon-reload && sudo systemctl enable --now voltmeter
- Defaults: ADS1115
0x48, OLED0x3C; change them inconfig.yaml. - Input dividers: set
device.adc.ch0_divider/ch1_divider(r_top,r_bottom) if a resistor divider sits ahead of an ADC input. Readings, formulas and logs then see the real input voltage (pin voltage × (r_top + r_bottom) / r_bottom). The menu "Range" is the ADC pin range, not the input range. - USB must be auto-mounted under a
usb.mount_rootsfolder (/media,/mnt,/run/mediaby default) (Pi OS desktop does this; on Lite installusbmountorudisks2+udiskie). Remove the stick before unplugging to avoid data loss; the CSV is flushed every row and fsynced every second. - Keep inputs within 0..VDD (+0.3 V) of the ADS1115.
Develop without hardware
pip install -e '.[dev]' && pytest
voltmeter --sim --home /tmp/vm # writes the screen to /tmp/voltmeter.png
Layout / extending
adc.pyADC backends ·formulas.py·settings.py·usb.py·ui.py(renders a PIL image) ·hardware.py(OLED/buttons) ·app.py(loop).- Every reading is a
Readingobject fanned out to sinks (sinks.py). For TigerData/Grafana, add a class withwrite(reading)/close()(batch + retry in a background thread so the sampling loop never blocks) and register it withApp.add_sink(...). Grafana reads from the TigerData (Postgres) table.
Web dashboard (Vercel)
web/ is a FastAPI app that shows the latest value of every channel, refreshed every 2 s
(/ is the page, /api/latest the JSON). It reads the readings table and applies each row's
stored formula name to its volts using the same formulas/*.txt and parser as the Pi.
- In
psql(as the admin user) rundb/readonly_role.sqlafter setting a password; the web app gets a SELECT-only role, never the admin or Pi credentials. - Run locally:
DATABASE_URL='postgres://voltmeter_web:PASSWORD@HOST:PORT/tsdb?sslmode=require' uvicorn app:app --reloadfromweb/(needspip install '.[web]'). - Optional but recommended: as admin run
db/timescale_setup.sql(continuous aggregatereadings_1m, compression after 1 day, 90-day retention). Then setREADINGS_AGG=readings_1m; history ranges of 6 h and longer read the aggregate instead of raw rows. - Deploy: import the repo in Vercel with Root Directory
web, framework "Other", and addDATABASE_URL(+READINGS_AGG) as environment variables. Every push tomainredeploys.web/must be self-contained, so it holds copies ofvoltmeter/formulas.pyandformulas/*.txt; after editing the originals runcp voltmeter/formulas.py web/voltmeter/ && cp formulas/*.txt web/formulas/(a test fails if they drift). GitHub Actions (.github/workflows/ci.yml) runs the tests.
Public demo: deploy a second Vercel project from the same repo (Root Directory web) with only DEMO_MODE=1 set and no DATABASE_URL. It serves simulated demo-cryo readings and cannot reach your database.
Themes: / is a clean instrument-panel look; /neon, /neo (neo-brutalist) and /nge (retrofuturist military) and /98 (Windows 98 via 98.css) are easter eggs.
Graph values are the average of each time bucket's converted readings: formulas are translated to SQL and applied to every row before averaging, so a non-linear formula (e.g. the pressure one) is not reduced to a geometric mean. The readings_1m aggregate stores mean volts, so ranges of 6 h or more use it only for formulas that are linear in V; other formulas read raw rows. Formulas that can't be translated to SQL (%, //, two-argument log) fall back to converting the mean volts.
The page has a history graph (1m to 24h, per device/channel, value or volts, linear or log).
Channels older than STALE_AFTER_S (30 s) are dimmed and marked stale. If a row names a formula
that is not in formulas/, the page falls back to showing volts.